Automatic configuration tuning

Version added: 1.3.0

The Operator can calculate a full MySQL configuration in addition to innodb_buffer_pool_size and max_connections. The calculation is based on the CPU and memory you allocate to the MySQL container, the workload you run, and the MySQL version. You set those resources and the Operator sizes the database settings to match them. When the resources change, the Operator recalculates the settings accordingly.

This automatic configuration tuning gives you:

  • Production-ready cluster tuned to its actual resources and workload out of the box
  • Effective resource utilization – you pay only for what you use
  • Updated settings when you change mysql.resources or the workload profile

The Operator uses the mysqloperatorcalculator library to calculate these settings. It sets [mysqld] variables only. Container resources, probe timings, and storage size stay under your control.

Availability

  • New clusters: enabled when you deploy with Operator 1.3.0+ and the crVersion is 1.3.0 or higher.
  • Existing clusters: upgrading the Operator does not turn automatic configuration tuning on for you. Turn it on yourself once you’ve upgraded.

Supported Percona Server for MySQL versions

The Operator can calculate MySQL settings for these Percona Server for MySQL versions:

  • 9.7.x
  • 8.4.x (all patch releases)
  • 8.0.46 and later

On 8.0.45 or older, the Operator falls back to basic buffer-pool and max_connections tuning. See AutoConfigFallback warning if you weren’t expecting it.

Turn on automatic configuration tuning

Important

If spec.mysql.configuration is set, or you have MySQL settings in your own ConfigMap or Secret, the Operator does not calculate the configuration even when automatic configuration tuning is turned on. See Automatic vs user-provided MySQL configuration for details. Clear those settings first if you want the Operator to calculate the MySQL configuration for you.

Configure the spec.mysql.autoConfig. section in the Custom Resource.

  • Set enabled to true.
  • Specify the workload profile in the loadType. See Choose a workload profile to understand which one you need.
  • When enabled is true, the following fields are required. The Custom Resource is rejected otherwise:

  • mysql.resources with both CPU and memory, set in requests or limits. CPU must be greater than 0 and memory must be at least 12Mi.

  • mysql.autoConfig.version, in the <major>.<minor>.<patch> format.
spec:
  mysql:
    autoConfig:
      enabled: true
      loadType: someWrites  
      version: "8.4.8"       # the MySQL version to tune for
    resources:
      requests:
        cpu: "2"
        memory: 4Gi
      limits:
        cpu: "4"
        memory: 8Gi

See the Custom Resource reference for the full field list.

Choose a workload profile

loadType tells the Operator how to balance read-oriented and write-oriented settings:

loadType Approximate read/write mix Choose this when
mostlyReads ~95% reads Reporting, blogs, or read-replica workloads rarely write
someWrites (default) ~80% reads A typical read-dominated application, such as e-commerce or light OLTP
equalReadsWrites ~50/50 Mixed analytics or heavy OLTP
heavyWrites Write-dominated Log ingestion, event streams, or high-frequency inserts

Understand how calculation works

When automatic configuration tuning is turned on, the Operator uses these inputs to calculate the configuration on every reconcile:

Input Source
CPU and memory mysql.resources. When both limits and requests are set, the Operator uses limits.
Workload profile mysql.autoConfig.loadType. See Choose a workload profile for available profiles and the default.
MySQL version mysql.autoConfig.version. This selects the parameter set — see Keep the MySQL version in sync.
Replication type mysql.clusterType. Group Replication and asynchronous replication receive different settings.

The Operator writes the result to the auto-<cluster-name>-mysql ConfigMap. It updates that ConfigMap only when the result changes, so a cluster with unchanged inputs does not restart.

Keep the MySQL version in sync

mysql.autoConfig.version tells the Operator which MySQL version to tune for. It does not change which image is deployed, and the Operator does not check that the two match. Update mysql.autoConfig.version whenever you change mysql.image. A mismatch can make the Operator emit a parameter the running server does not recognize, and that can prevent MySQL from starting.

Automatic vs user-provided MySQL configuration

The Operator calculates the full configuration only when the spec.mysql.configuration in the Custom Resource is empty and you have not put MySQL settings in a ConfigMap or Secret of your own.

Any value in spec.mysql.configuration or any MySQL settings in a ConfigMap or Secret you create disable automatic configuration tuning. The Operator applies only your settings plus the innodb_buffer_pool_size, innodb_buffer_pool_chunk_size, and max_connections values that it calculates from the container memory. It logs a user configuration is set, skipping autoconfig message and does not record a Kubernetes event for this skip.

The auto-<cluster-name>-mysql ConfigMap is the Operator’s output. It does not count as configuration you supplied.

The Operator calculates the full configuration once you’ve turned it on and cleared spec.mysql.configuration and removed MySQL settings from your own ConfigMap or Secret.

Full list of tunable variables

The Operator includes a variable only when mysql.autoConfig.version falls inside that variable’s supported range. Read the ConfigMap to see the variables and values for your cluster:

kubectl get configmap auto-<cluster-name>-mysql -o jsonpath='{.data.my\.cnf}' -n <namespace>
InnoDB, connections, binlog, replication, and Group Replication variables

InnoDB, on every cluster:

  • innodb_buffer_pool_size, innodb_buffer_pool_instances, and innodb_buffer_pool_chunk_size
  • innodb_redo_log_capacity, or innodb_log_file_size and innodb_log_files_in_group on MySQL 8.0
  • innodb_flush_method and innodb_flush_log_at_trx_commit
  • innodb_io_capacity_max, innodb_purge_threads, and innodb_parallel_read_threads
  • innodb_adaptive_hash_index, innodb_numa_interleave, and innodb_monitor_enable

Connections and session buffers, on every cluster:

  • max_connections and thread_cache_size
  • join_buffer_size, sort_buffer_size, and read_rnd_buffer_size
  • tmp_table_size, max_heap_table_size, and sync_binlog

Replication applier, on every cluster:

  • replica_parallel_workers and replica_parallel_type
  • replica_preserve_commit_order, replica_exec_mode, and replica_compressed_protocol

Binary logging and asynchronous replication, on asynchronous replication clusters:

  • binlog_cache_size, binlog_stmt_cache_size, binlog_format, binlog_row_image, and binlog_expire_logs_seconds
  • gtid_mode and enforce_gtid_consistency
  • relay_log_space_limit, sync_relay_log, replica_net_timeout, and replica_checkpoint_period

Group Replication, on Group Replication clusters:

  • group_replication_message_cache_size and group_replication_communication_max_message_size
  • group_replication_flow_control_period and group_replication_member_expel_timeout
  • group_replication_autorejoin_tries and group_replication_paxos_single_leader
  • binlog_transaction_dependency_tracking

How calculated settings are applied

The Operator applies calculated values after all MySQL Pods are ready:

  • Variables that MySQL accepts at runtime are applied with SET GLOBAL on each Pod, with no restart.
  • The buffer pool, redo log settings and variables that MySQL accepts only at startup cause a rolling restart of the MySQL StatefulSet. Removing a variable from the configuration also causes a rolling restart.

Changing mysql.resources changes the buffer pool and the redo log. This change usually restarts the MySQL Pods. Plan a resize of mysql.resources as a change-management event. See Scale compute resources.

Before the Operator writes the configuration, it checks the calculated redo log against the data volume. When the redo log would exceed 25% of that volume, reconciliation stops. See AutoConfigInsufficientStorage warning.

Troubleshoot automatic configuration tuning

Check the cluster events first. See Check the Events.

kubectl get events --field-selector involvedObject.name=<cluster-name>

AutoConfigInsufficientStorage warning

Symptom. Reconciliation is stuck. kubectl get events shows a warning with reason AutoConfigInsufficientStorage. The message names the calculated redo log size, the data volume size, and the minimum volume size needed.

Cause. The redo log size follows the buffer pool, and the buffer pool follows the memory in mysql.resources. MySQL preallocates the full redo log on disk. The Operator refuses a configuration whose redo log would exceed 25% of the data volume, so a volume that is too small does not reach a server that fails to start or clone.

The Operator uses the capacity of the smallest existing MySQL data volume in the cluster. When no PersistentVolumeClaims exist yet, it uses the storage size in mysql.volumeSpec. When the size cannot be determined, for example with a hostPath volume or an emptyDir volume without sizeLimit, the Operator skips this check.

Fix. Do one of the following, then let the Operator reconcile again:

  • Increase the storage size of the MySQL data volume.
  • Lower the memory in mysql.resources so the Operator sizes a smaller buffer pool and redo log.

AutoConfigFallback warning

Symptom. The cluster starts, and events include a warning with reason AutoConfigFallback.

Cause. The Operator could not calculate the full configuration. It uses the basic buffer pool and max_connections tuning instead. Typical causes are a missing CPU value, an unsupported MySQL version, or an internal calculation error.

A configuration you set yourself also skips automatic configuration tuning, and that skip is written to the Operator log only. See Automatic vs user-provided MySQL configuration.

AutoConfigFailed warning

Symptom. Events include a warning with reason AutoConfigFailed.

Cause. The basic buffer pool and max_connections tuning also failed. MySQL starts with no calculated parameters.